Adjustable autologous sling for recurrent female SUI: Restoring continence and sexual function

Leeland Rincon P1, Coloma del Peso A1, Barrera Rodriguez C1, Gómez-Acebo Núñez M1, De la Peña González G1, Rodríguez Molina M1, Martín Arroyo L1, Sinues Ojas B1, Sánchez Ramírez A1, Fernández Arjona M1

Research Type

Clinical

Abstract Category

Female Stress Urinary Incontinence (SUI)

Abstract 46
Surgical Videos 1 - Urogynaecology Techniques
Scientific Podium Video Session 6
Wednesday 7th October 2026
12:07 - 12:15
Parallel Hall 4
0.10 Sydney
Capacity: 265
Female Grafts: Biological Stress Urinary Incontinence Surgery Quality of Life (QoL)
1. Hospital del Henares, Coslada, Madrid
Presenter
Links

Abstract

Introduction
The treatment of stress urinary incontinence (SUI) with synthetic mesh provides good outcomes; however, it may be associated with complications, particularly in patients with prior mesh extrusion or chronic pelvic pain, impacting quality of life. In this context, autologous grafts combined with adjustable systems represent a safe and effective alternative.
We aim to describe the surgical technique of an autologous rectus fascia sling using a tension-free vaginal tape (TVT)-like approach combined with an adjustable system (REEMEX), through a surgical video, and to evaluate its functional and sexual outcomes.
Design
We present the case of a 48-year-old woman who underwent a transobturator sling for SUI in 2015 and required mesh excision in 2017 due to extrusion, subsequently developing chronic pelvic pain refractory to conservative treatment. In 2024, she presented recurrent SUI.

Cystoscopy was normal. Pelvic magnetic resonance imaging showed findings consistent with myofascial syndrome. Urodynamic evaluation confirmed SUI, with no evidence of bladder outlet obstruction or detrusor overactivity.

Surgery was performed under epidural anesthesia. An autologous rectus fascia graft was harvested through a suprapubic Pfannestiel incision and prepared with polypropylene sutures for connection to the REMEX system. Through a vaginal approach with anterior colpotomy and retropubic passage of the sutures, the graft was positioned at the mid-urethra and connected to the suprapubic adjuster. Intraoperative cystoscopy excluded bladder perforation, and a mild initial adjustment was performed.
Results
The patient was discharged 24 hours postoperatively without the need for readjustment, with negligible post-void residual. At four-month follow-up, she reported no urinary leakage and a marked improvement in quality of life. Sexual function, assessed using the validated Spanish version of the PISQ-IR questionnaire, showed significant improvement. Uroflowmetry was normal (Qmax 16.7ml/s), with negligible post-void residual.
Conclusion
The combination of an autologous sling with an adjustable system allows restoration of a dynamic and physiological continence mechanism while avoiding synthetic material. It represents a safe and effective option in complex or recurrent SUI, with a positive impact on sexual function and quality of life.
Disclosures
Funding None Clinical Trial No Subjects Human Ethics not Req'd This is a descriptive surgical video of a single clinical case, without any experimental intervention or deviation from standard clinical practice. Therefore, ethics committee approval was not required. Informed consent for the procedure and for video recording and presentation was obtained Helsinki Yes Informed Consent Yes AI For simple textual assistance in writing the abstract manuscript
Citation

Continence 19S (2026) 102523
DOI: 10.1016/j.cont.2026.102523

31/10/2026 16:44:22